33-14. RIGHT REAR FLOOR PANEL REPAIR (Contd)
TM 9-2320-387-24-2
Change 1
33-97
1.
Position reinforcement strip A (3) on insert panel (1). Align reference lines (2) with edge of
reinforcement strip A (3).
2.
Using reinforcement strip A (3) as a template, locate, mark, and drill fourteen 0.187-in.
(4.75-mm) diameter holes through insert panel (1). Remove reinforcement strip A (3).
3.
Apply approximately 0.125-in. (3.175-mm) thickness of adhesive sealant to shaded surface of insert
panel (1) and reinforcement strip A (3).
4.
Position reinforcement strip A (3) on insert panel (1) and install with fourteen rivets (4).
5.
Remove any adhesive residue and clean edges of reinforcement strip A (3) and insert panel (1).
e. Reinforcement Strip A and Insert Panel Assembly
DRILL FOURTEEN 0.187-IN. (4.75-MM)
DIAMETER HOLES