TM 9-2330-392-14&P
Change 2
4-32.5
4-19.3
BRANCHED WIRING HARNESS REPAIR (Cont).
b.
TYPICAL PLUG REPLACEMENT
1.
Remove nut (16) from shell assembly (13) and slide back on cable (17).
2.
Push grommet (10) back on cable leads (9).
3.
Slide coupling nut (15) off shell assembly (13).
4.
Push contacts (11) out through rear of insert (14) with pin extractor.
5.
Push insert (14) out through rear of shell (13).
6.
Unsolder cable leads (9) from contacts (11).
7.
Remove coupling nut (15) and grommet (10) from cable (17).
8.
Strip cable insulation from leads (9) equal to depth of solder wells of contacts (11).
9.
Slip grommet (10) over cable leads (9).
10. Insert cable leads (9) into solder wells of contacts (11) and solder.
11. Slide coupling nut (15) over contacts (11) at cable leads (9).
12. Push insert (14) into shell (13) from rear until seated. Groove (12) in insert (14) must be aligned with guide in
shell (13) to ensure proper fit.
13. Push contacts (11) into insert (14) from rear until seated.
14. Slide coupling nut (15) onto shell assembly (13).
15. Push grommet (10) down cable leads (9) and over solder wells of contacts (11).
16. Install nut (16) on shell assembly (13).