TM 9-2330-392-14&P
4-32.4
Change 2
4-19.3
BRANCHED WIRING HARNESS REPAIR (Cont).
a.
TYPICAL PANEL MOUNTING RECEPTACLE REPLACEMENT
1.
Remove nut (7) from shell assembly (4) and slide back on cable (8).
2.
Push grommet (2) back on cable leads (1).
3.
Push contacts (6) out through rear of insert (5) with pin extractor.
4.
Push insert (5) out through rear of shell (4).
5.
Unsolder cable leads (1) from contacts (6).
6.
Remove grommet (2) from cable leads (1).
7.
Strip cable insulation from leads (1) equal to depth of solder wells of contacts (6).
8.
Slide grommet (2) over cable leads (1).
9.
Insert cable leads (1) into solder wells of contacts (6) and solder.
10. Push insert (5) into shell (4) from rear until seated. Groove (3) in insert (5) must be aligned with guide in shell (4)
to ensure proper fit.
11. Push contacts (6) into insert (5) from rear until seated.
12. Push grommet (2) down cable leads (1) and over solder wells of contacts (6).
13. Install nut (7) on shell assembly (4).