TM 9-2330-392-14&P
4-32.6
Change 2
4-19.3
BRANCHED WIRING HARNESS REPAIR (Cont).
c.
TERMINAL-TYPE CABLE CONNECTOR REPLACEMENT
1.
Strip insulation from cable (18) equal to depth of terminal (20) well.
2.
Slide insulator (19) over cable (18).
3.
Insert cable (18) into terminal (20) well and crimp.
4.
Slide insulator (19) over crimped end of terminal (20).
d.
MALE CABLE CONNECTOR REPLACEMENT
1.
Strip insulation from cables (21) equal to depth of ferrule (24) well.
2.
Slide shell (22) over cable (21) and remove C-washer (23).
3.
Insert cable (21) into ferrule (24) well and crimp.
4.
Place C-washer (23) over cable (21) at crimped junction and slide shell (22) over C-washer (23) and ferrule (24).