11-86. CONDENSER FAN ACCESS PANEL MAINTENANCE
This task covers:
a. Removal
c. Installation
b. Inspection
1.
Remove three capscrews (9), washers (8), and bracket (7) from access panel (2).
2.
Remove capscrew (9.1) and washer (9.2) from access panel (2).
3.
Remove three self-tapping screws (4), washers (3), and access panel (2) from condenser tray (11) and
cargo shell (1).
4.
Remove two screws (6) and footman loop (5) from access panel (2).
Refer to para. 10-56 for plusnut (10) inspection and replacement.
1.
Install footman loop (5) on access panel (2) with two screws (6).
2.
Install access panel (2) on condenser tray (11) and cargo shell (1) with three washers (3) and
self-tapping screws (4).
3.
Apply sealing compound to threads of capscrews (9), and install bracket (7) on access panel (2) with
three washers (8) and capscrews (9). Tighten capscrews (9) to 10 lb-ft (14 Nm).
4.
Apply sealing compound to threads of capscrew (9.1), and install washer (9.2) and capscrew (9.1) on
access panel (2). Tighten capscrew (9.1) to 10 lb-ft (14 Nm).
c. Installation
b. Inspection
a. Removal
INITIAL SETUP:
Applicable Models
M1114
Tools
General mechanics tool kit:
automotive (Appendix B, Item 1)
Maintenance and repair shop equipment:
automotive (Appendix B, Item 2)
Manual References
TM 9-2320-387-24P
Materials/Parts
Sealing compound (Appendix C, Item 72.1)
Equipment Condition
Condenser fan exhaust vents removed
(para. 11-85).
Cargo shell door gas spring mounting bracket
removed (para. 11-29).
Maintenance Level
Unit
TM 9-2320-387-24-2
11-154
Change 1