4-18. EES KIT INSTALLATION (Contd)
w. 200 Amp Alternator Ground Strap Installation
1.
2.
3.
4.
5.
NOTE
Ensure terminal is clean before connection is made.
Apply copper shield sparingly to bolt (8) surface of ground
strap (4),
Insert bolt (8) through hole in ground strap (4).
Install bolt (8) and ground strap (4) to upper hole on mounting
bracket (6).
Tighten to 48 lb-ft (65 N·m).
Remove nut (1), lockwasher (2), and lead 3B (3) from ground
stud (7) on 200 amp alternator (5).
Retain lockwasher (2) for
installation.
Install ground strap (4) and lead 3B (3) to ground stud (7) and
secure with lockwasher (2) and nut (1).
Tighten nut (1) to
96-144 lb-in. (11-16 N·m).