TM 9-2320-362-14&P
4-18. EES KIT INSTALLATION (Contd)
q. Water Pump Pulley Installation
1.
Clean threads of four sockethead screws (1) retained from removal
of water pump pulley (TM 9-2320-280-20).
2.
Install water pump pulley (2) on water pump (3).
3.
Apply sealing compound to four sockethead screws (1).
40
Secure water pump pulley (2) to water pump (3) with four
sockethead screws (1).
5.
Using 6mm hex socket wrench attachment, tighten sockethead
screws (1) to 180-240 lb-in. (20-27 N m).
4-58