TM 9-2320-280-10
Table 2-2. Preventive Maintenance Checks and Services (Contd)
Location
Item
Item to
Crewmember
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
DRIVER
(M996, M996A1, M997,
M997A1, and M997A2 only)
29
After
Patient
a. Check presence and
a. One or more
Compart-
operation of ceiling white
lights inoperative or
ment
lights, blackout lights, and
unserviceable.
spotlights.
b. Check operation of
b. Any blackout
blackout switches at rear
switch inoperable.
step, rear doors, and bulk-
head door.
c. Inspect condition and
security of litter racks and
components.
d. Inspect upper litter rack
d. Hinges or latches
hinges and latches for
inoperative, dam-
proper operation, damage,
aged, or missing.
or missing components.
e. Inspect tension straps, sup-
port straps, litter straps, and
footman loops for security of
mounting, damage, and
missing components.
f. Inspect oxygen bottles and
mounting components for
security of stowage when
oxygen bottles are in
stowed position.
g. Inspect IV straps and
hangers for security of
mounting, damage, and
missing components.
2-81