33-13. RIGHT FRONT FLOOR PANEL REPAIR (Contd)
TM 9-2320-387-24-2
33-74
Change 1
1.
Position metal strip A (2), with arrow facing up and toward left, on insert panel (1). Align reference
line (3) with edge of metal strip A (2) and reference lines (5) with edge of insert panel (1).
2.
Using metal strip A (2) as a template, locate, mark, and drill ten 0.187-in. (4.75-mm) diameter
holes through insert panel (1). Remove metal strip A (2).
3.
Apply approximately 0.125-in. (3.175-mm) thickness of adhesive sealant to shaded surface of insert
panel (1) and metal strip A (2).
4.
Position metal strip A (2) on insert panel (1) and install with ten rivets (4).
5.
Remove any adhesive residue and clean edges of metal strip A (2) and insert panel (1).
d. Metal Strip A and Insert Panel Assembly
DRILL TEN 0.187-IN. (4.75-MM) DIAMETER HOLES