33-12. LEFT REAR FLOOR PANEL REPAIR (Contd)
TM 9-2320-387-24-2
33-56
Change 1
1.
Position metal strip D (1), with arrow facing up and toward metal strip C (4), on insert panel (2).
Align reference lines (3).
2.
Using metal strip D (1) as a template, locate, mark, and drill seven 0.187-in. (4.75-mm) diameter
holes through insert panel (2). Remove metal strip D (1).
3.
Apply approximately 0.125-in. (3.175-mm) thickness of adhesive sealant to shaded surface of insert
panel (2) and metal strip D (1).
4.
Position metal strip D (1) on insert panel (2) and install with seven rivets (5).
5.
Remove any adhesive residue and clean edges on metal strip D (1) and insert panel (2).
h. Metal Strip D and Insert Panel Assembly
DRILL SEVEN 0.187-IN. (4.75-MM) DIAMETER HOLES