TM 9-2320-387-24-l
4-68 . BATTERY CABLE MAINTENANCE (Co&d)
1 d. Ground Cable Removal
1
Remove screw (21,
lockwasher (61, ground cable (51, and slave cable (4) from shunt (1) and battery
box (3). Discard lockwasher (6).
e. Ground Cable Installation
Install slave cable (4) and ground cable (5) on shunt (1) and battery box (3) with lockwasher (6) and screw (2).