TM9-2320-387-24-l
4-68. BATTERY CABLE MAINTENANCE (Contd)
b. Ground Cables Diconnection
1. Remove nut (121,
screw
(14),
and cable (1) from terminal clamp (13).
2.
Remove cap (5) from battery terminal boot (8).
3.
Clean lubricating oil from battery terminal boot (8).
4.
Loosen nut (7) and remove terminal clamp (4) from terminal (9).
5.
Remove nut (3) and screw (6) from cable (2) and terminal clamp (4).
6.
Remove cable (2) from terminal clamp (4) and battery terminal boot (8).
c. Ground Cables Reconnection
1.
Push battery terminal boot (8) onto cable (2) and secure cable (2) to terminal clamp (4) with screw (6)
and nut (3).
2.
Apply a 1/16-in. (1.~mm) bead of lubricating oil to battery post pad (10). Do not allow oil to coat
terminal post (9).
3.
Install terminal clamp (4) on terminal (9) and tighten nut (7).
4.
Fill battery terminal boot (8) with lubricating oil.
5.
Install cap (5) on battery terminal boot (8).
6.
Install cable (1) on terminal clamp (13) with screw (14) and nut (12).
4-111