1 l-20. COOLING SYSTEM OPERATION (Contd)
1
0 I
0 J
0 K
0 L
0 M
0 N
0 0
0 P
FAN - Pulls outside air through radiator to remove heat from coolant.
HYDRAULIC
CONTROL VALVE - Directs hydraulic fluid to provide required pressure to actuate
fan clutch as required by engine temperature. Hydraulic pressure is supplied by power steering
pump.
TIME DELAY MODULE - Sends delayed signal to fan clutch solenoid for delay of fan actuation to
provide needed horsepower for engine acceleration.
FAN CLUTCH SOLENOID - Actuates hydraulic control valve as required by coolant temperature.
WATER PUMP - Driven by serpentine belt, provides circulation of coolant through cooling system.
FAN CLUTCH - Hydraulically actuated by pressure from hydraulic control valve to control
operation of fan. Hydraulic pressure is supplied by power steering pump.
DR.AINVAIXE - Draining point for radiator and cooling system.
RADIATOR SHROUD - Permits a greater concentration of air to be pulled through the radiator.
1-27