REFERENCE INFORMATION
Measure from the positive post to the
negative post of each battery.
For battery replacement instructions,
refer to para. 4-74.
NOTE
Check these cables:
WIRE 68, connecting the batteries
together. lest point is the postive
terminal of one of the batteries.
WIRE 49A, connecting the batteries
to the power stud. lest point is the
power stud.
Wire connecting the battery to the
shunt. Test point is the shunt.
Wire connecting shunt to ground
stud. Test point is the shunt.
For repair or replacement of cables,
refer to para. 4-68.
If you use STEZE-R
test 67 in Step
3 on page 2-252, you may have a
faufty DCA. Try running the tests
using STE/ICE-R test 89 with the
W2 cable.
See para. 4-74. (Also check each
batterys specific gravity in accordance
with TM 9-6140-200-14.)
Replace battery (para. 4-74).
TM 9-2320-387-24-l
BAlTERY CIRCUIT
DC VOLTAGE O-45 VOLTS
STEYICE-R TEST 89
1. Connect RED clip to the indicated test point.
BLACK dip to negative or ground.
2. Start Test 89, DC Volts.
3. Displayed reading is in volts.
2-243