TM 9-2320-280-20-3
Change 1
D-46.1
Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd)
200 AMP ALTERNATOR CABLE ASSEMBLY
CABLE
CUT LENGTH
MANUFACTURED
END TERMINAL
END INSULATOR
PART NUMBER
(INCHES)
FROM NSN
NSN
NSN
5582451
58
6145-00-705-6674
5940-00-735-5520
5970-00-174-9449
INSTRUCTIONS:
1.
Cut cable to length as shown.
2.
Cut 14 inches of spiral wrap from bulk and install as shown. Secure spiral wrap in position with
black tape at both ends.
3.
Select and solder proper end terminals to cable ends as shown. (Refer to TM 9-237 for soldering
instructions.)
4.
Install insulator and insulator boot to cable ends as shown.
5.
Mark and install identification bands using old cable as reference.
Figure D-62. 200 Amp Alternator Cable Assembly.
MATERIAL BLOCK
STOCK SIZE
DESCRIPTION
SPECIFICATION
"O" GAGE
WIRE, ELECTRICAL
MIL-C-13486