TM 9-2320-280-20-3
Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd)
D-46.2
Change 1
12 VOLT ALTERNATOR CABLE ASSEMBLY
CABLE
CUT LENGTH
MANUFACTURED
END TERMINAL
END INSULATOR
PART NUMBER
(INCHES)
FROM P/N
PART NUMBER
PART NUMBER
12446821
102
M13486/1-9
MS20659-108
12460417
MATERIAL BLOCK
STOCK SIZE
DESCRIPTION
SPECIFICATION
"O" GAGE
WIRE, ELECTRICAL
MIL-C-13486
INSTRUCTIONS:
1.
Cut cable to length as shown.
2.
Cut of 92.50 inches spiral wrap from bulk and install as shown. Secure spiral wrap in position with
tape at both ends.
3.
Select and solder proper end terminals to cable ends as shown. (Refer to TM 9-237 for soldering
instructions.)
4.
Install insulator and insulator boot to cable ends as shown.
5.
Mark and install identification bands using old cable as reference.
Figure D-62.1. 12 Volt Alternator Cable Assembly.