TM 9-2320-280-20-2
4-6.10
Change 2
4-2.2. 100/200 AMPERE ALTERNATOR CABLE REPLACEMENT(Contd)
NOTE
Prior to removal, tag leads for installation.
Note number of clamps and tiedown straps for installation.
1. Slide back rubber boot (9) and remove nut (12), washer (13), and cable (11) from regulator (10).
2. Remove six tiedown straps (8) from cables (1), (6), and (11). Discard tiedown straps (8).
3. Remove nut (5), lockwasher (4), washer (3), clamp (2), and cables (1) and (6) from stud (7). Discard
lockwasher (4).
4. Remove nut (16), lockwasher (15), washer (14), clamp (17), and cables (1) and (6) from stud (18).
Discard lockwasher (15).
5. Remove screw (20), clamp (19), nut (27), lockwasher (26), screw (22), washer (23), clamp (24), and
cables (1) and (6) from bracket (25) and body (21). Discard lockwasher (26).
c. 12-Volt Regulator Cable Removal