TM 9-2320-280-20-1BATTERY CURRENT TEST #80Description:This procedure measures current to or fromthe battery. Test requires DCA hookup only.Typical Applications:Evaluate batteries in Cl engines.Teat Procedure:1. set TEST SELECT switch to 80.2. Press and hold TEST button until CALappears on display.3. Release TEST button and wait for offsetvalue to appear on display. If offset is within-150 to 150, proceed. lf not, go to DCATroubleshooting Procedure.4. Press and release TEST button.5. Observe displayed value (amps).Pre-Test Procedures:Run Confidence Test.Control Functions01,02,03,04Possible Error Messages:E005 Offset not Performed.2-749