REFERENCE INFORMATION
TM 9-2320-280-20-1
BATTERY CIRCUIT
Measure from the positive poet to the
negative poet of each battery.
For battery replacement instructions,
refer to (para. 4-79).
NOTE
Check these cables:
WIRE 68, connecting the batteries
together. Test point is the postive
terminal of one of the batteries.
WIRE 49A, connecting the batteries
to the power stud. Test point is the
power stud.
Wire connecting the battery to the
shunt. Test point is the shunt.
Wire connecting shunt to ground
stud. Test point is the shunt.
For repair or replacement of cables,
refer to (para. 4-73).
If you use STE/lCE-R test 67 in Step
3 on page 2-252, you may have a
faulty DCA. Try running the tests
using STE/lCE-R test 89 with the
W2 cable.
Sea paragraph 4-79. (Also check each
battery's specific gravity in accordance
with TM 9-6140-200-14.)
0-45 DC VOLTS
STE/lCE-R TEST 89
1. Connect RED clip to the indicated test point,
BLACK cIip to negative or ground.
2. Start Test 89, DC volts.
3. Displayed reading is in volts.
Replace battery refer to (para. 4-79).
2-257