TM 9-2320-387-24-l
4-l 4. INSTRUMENT CLUSTER REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
Tools
General mechanics tool kit:
automotive (Appendix B, Item 1)
Materials/Parts
Five lockwashers (Appendix G, Item 206)
Antiseize compound (Appendix C, Item 16)
Manual References
TM 9-2320-387-10
TM 9-2320-387-24P
Equipment Condition
Battery ground cables disconnected (para. 4-68).
Maintenance Level
Unit
NOTE
Prior to removal, tag leads for installation.
1.
Remove four screws (7) and washers (6) from instrument cluster (8) and instrument panel (3). Pull
instrument cluster (8) away from instrument panel (3) to allow access to speedometer cable (4).
2.
Loosen driveshaft nut (5) and disconnect speedometer cable (4) from speedometer (1).
3.
Disconnect harness lead 275 (26), 28A (9), 40B (13), 27H (14), 36A (15),57L (19),17B (201, 27G (21),
33A (22), 40C (171, and 567A (18) from instrument cluster (8).
4.
Remove five nuts (12),lockwashers (111, and harness ground leads 58H (10),58G (25), 58E (23), 58F (241,
and 57G (16) from instrument cluster (8) and remove instrument cluster (8). Discard lockwashers (11).
4-30