3-62. RADIATOR AND FAN SHROUD ASSEMBLY MAINTENANCE (Cont'd)
TM 9-2320-387-24-1
3-116
Change 1
NOTE
Fan shroud should be aligned so the following dimensions are
maintained. Adjustments may be made by sliding the radiator/shroud
assembly. Distance A from the edge of shroud ring and rear edge of fan
must be 1-1/2 ± 1/4 in. (38.1 ± 6 mm). Measure distance A at the 2, 4, 8,
and 10 oclock positions.
Fan blade to fan shroud clearance, distance between the top of the fan
blade and fan shroud, must not be less than 1/4 in. (6 mm) at any
position.
8.
Align fan shroud (11) and tighten four locknuts (10) to 26 lb-ft (35 Nm). Tighten capscrew (7) to
30 lb-ft (41 Nm).
9.
Connect lower radiator front hose (9) to radiator (3) and tighten clamp (8) to 85-95 lb-in
(9.6-10.7 Nm).
10.
Connect fan drive hose (15) to fan drive (16).
11.
Connect elbow (14) to bulkhead adapter (13).
12.
Connect control valve hose (12) to elbow (14).
13.
Connect radiator inlet hose (1) to radiator (3) and tighten clamp (2) to 85-95 lb-in (9.6-10.7 Nm).
14.
Connect surge tank-to-radiator vent hose (4) to adapter (6) and tighten clamp (5) to 10-20 lb-in
(1-2 Nm).