3-20. AIR RESTRICTION GAUGE HOSE REPLACEMENT
This task covers:
a. Removal
b.
Installation
a. Removal
1.
Loosen five clamps (2) securing hose (5) to A-beam (1).
2.
Disconnect hose (5) from air cleaner assembly (8).
3.
Disconnect hose (5) from gauge (3) located behind instrument panel (4).
4.
Remove hose (5) from five clamps (2) and through grommet (6) in cowl (7).
INITIAL SETUP:
Tools
General mechanics tool kit:
automotive (Appendix B, Item 1)
Manual References
TM 9-2320-387-10
TM 9-2320-387-24P
Equipment Condition
Hood raised and secured (TM 9-2320-387-10).
Maintenance Level
Unit
b. Installation
1.
Route hose (5) through grommet (6) and five clamps (2) in cowl (7) and connect hose (5) to air cleaner
assembly (8).
2.
Connect hose (5) to gauge (3).
3.
Tighten five clamps (2) on hose (5) and A-beam (1).
TM 9-2320-387-24-1
3-36
Change 1
FOLLOW-ON TASK: Lower and secure hood (TM 9-2320-387-10).
1
3
4
5
6
7
5
8
2
2