TM 9-2320-362-14&P
4-13. FREON LINES REPLACEMENT (Contd)
14.
Place insulation (10) and (13) around suction hose (14) and
discharge hose (7).
Secure insulation to hoses with
tie-straps (9).
15.
Install lanyard (11) from large dust cap through swaging
sleeve (12).
Loop lanyard (11) around suction hose (14) and back
through swaging sleeve (12). Crimp swaging sleeve (12).
16.
Install lanyard (11) from small dust cap through swaging
sleeve (12).
Loop lanyard (11) around discharge hose (7) and back
through swaging sleeve (12). Crimp swaging sleeve (12).
17.
Connect suction hose (14) and discharge hose (7) to quick
disconnects (15) and (6).
18.
Install cover (4) to freon line channel (5) and secure with four
screws (1), lockwashers (2), and washers (3).
4-32