TM 9-2320-362-14&P
4-13. FREON LINES REPLACEMENT (Contd)
b. Installation
1.
2.
3.
4.
5.
6.
7.
8.
Cut insulation (1) from upper section of suction hose (2) as
follows:
(a) Measure 11 in. (27.94 cm) from end of suction hose (2) and
make circular cut around insulation (1).
(b) Cut insulation 22 in. (55.88 cm) lengthwise.
(c) Make another circular cut around insulation (1) at 33 in.
(83.82 cm).
Remove insulation (1) from suction hose (2).
Trim removed insulation (1) 3 in. (7.62 cm).
Cut insulation (4) from upper section of discharge hose (3) as
follows:
(a) Measure 33 in. (83.82 cm) from end of discharge hose (3) and
make circular cut around insulation (4).
(b) From end of discharge hose (3), cut insulation lengthwise
until circular cut is reached.
Remove insulation (4) from discharge hose (3).
Trim removed insulation (4) 3 in. (7.62 cm).
Pull suction hose (2) up through hole (6) in transmission
tunnel (5).
Pull discharge hose (3) up through hole (6) in transmission
tunnel (5).
4-28