TM 9-2320-362-14&P
4-13. FREON LINES REPLACEMENT (Cont'd)
WARNING
Air conditioner system must be discharged prior
to replacing components in vapor system.
Failure
to do this may result in injury to personnel or
damage to equipment.
CAUTION
Cover or plug all open lines and connections
immediately after disconnection to prevent
contamination.
Remove all plugs prior to
connection.
NOTE
Suction hose (low pressure) has a larger diameter
than the discharge hose (high pressure); fittings
will not interconnect.
1.
Remove capscrew (5), two washers (4), and self-locking nut (6)
that secure clamp (3), suction hose (7), and discharge hose (2) to
underside of body.
Discard self-locking nut (6).
2.
Remove tie-straps (1) that secure suction hose (7) and discharge
hose (2) together.
Discard tie-straps (1).
4-22