1-20. COOLING SYSTEM OPERATION (Cont'd)
FAN - Pulls outside air through radiator to remove heat from coolant.
HYDRAULIC CONTROL VALVE - Directs hydraulic fluid to provide required pressure to actuate
fan clutch as required by engine temperature. Hydraulic pressure supplied by power steering pump.
TIME DELAY MODULE - Sends delayed signal to fan clutch solenoid for delay of fan actuation to
provide needed horsepower for engine acceleration.
FAN CLUTCH SOLENOID - Actuates hydraulic control valve as required by coolant temperature.
WATER PUMP - Driven by V-belts provides circulation of coolant through cooling system.
FAN CLUTCH - Hydraulically actuated by pressure from hydraulic control valve to control
operation of fan. Hydraulic pressure supplied by power steering pump.
DRAINCOCK - Draining point for radiator and cooling system.
RADIATOR SHROUD - Permits a greater concentration of air to be pulled through the radiator.