TM 9-2320-280-20-1
REFERENCE INFORMATION
GLOWPLUGS CIRCUIT
Change 1 2-318.15/(2-318.16 blank)
CONTINUITY (RESISTANCE)
MULTIMETER
1. Set the voltmeter to an ohms scale of about 1000
ohms.
2. Connect the RED and BLACK leads to the
connections stated in the question.
3. Be sure to read the correct scale. Less than 5
ohms indicates continuity. For an open circuit, the
meter should peg full scale (needle all the way to
the left).
0-4500 OHMS
STE/ICE-R TEST 91
1. Connect RED clip and BLACK clip to the
indicated test points in the question. RED to the
first, BLACK to the second.
2. Start Test 91, 0-4500 ohms.
3. Displayed reading is in ohms. Less than 5 ohms
is continuity. If the resistance is over 4500 ohms,
STE/ICE displays 9.9.9.9.
Repair wiring or replace harness, refer to
(para. 4-85).
Replace glowplug controller, refer to
(para. 4-29).
Disconnect negative battery cable before
disconnecting and reconnecting
distribution box harness.
There is battery voltage at the distribution box at
all times. Failure to disconnect battery cable will
result in damage to equipment or injury to
personnel.
WARNING
Repair wiring or replace harness, refer to
(para. 4-84).