TM 9-2320-280-20-1
REFERENCE INFORMATION
ALTERNATOR
Change 1 2-213
0-45 DC VOLTS
STE/ICE-R TEST 89
1. Connect RED clip to the indicated test point,
BLACK clip to negative or ground.
2. Start Test 89, DC volts.
3. Displayed reading is in volts.
1. Disconnect battery ground cable.
2. Remove four screws, lockwashers, gasket, and
cover from regulator.
3. Remove potting material as necessary to gain
access to studs.
Replacement of Reverse Polarity Fuse
1. Remove nut, lockwasher, washer, fuse, insulator
and cable 6 from output stud.
2. Examine fuse for burns and breaks. Replace fuse
and insulator if damaged.
3. Install new fuse and insulator on output stud with
washer, lockwasher, and nut. Tighten nut 10-15
lb-in. (14-20 Nm).
For 60 amp Prestolite alternator, go to B, page 2-204.
For 100 amp Prestolite alternator, go to C, page 2-208.
For 200 amp Prestolite alternator, continue D.
For 200 amp single voltage Niehoff alternator, go to E, page
2-218.
For 100 amp single voltage Niehoff alternator, go to F, page
2-222.
For 100 amp dual voltage Niehoff alternator, go to F.1,
page 2-224.2.
For 200 amp dual voltage Niehoff alternator, go to G,
page 2-224.6.
For 400 amp dual voltage Niehoff alternator, go to H,
page 2-224.10.
NOTE