TM 9-2320-387-24-2
Change 1
18-10.3
18-3.1. 400-AMPERE DUAL VOLTAGE ALTERNATOR TESTING AND REPAIR (Cont'd)
12.
Position chain mounting assembly over alternator (25) and secure to adapter mount (1).
13.
Loosen locking handle (10) on bracket (9), lower bracket (9) to obtain tension on
serpentine belt (11), and tighten locking handle (10).
14.
Adjust support plate (4) on adapter mount (1) until support plate (4) contacts floor surface and
tighten screws (2) and (6) and nuts (7) and (8).
11
12
500-AMP ALTERNATOR/
GENERATOR/STARTER
TEST STAND
500-AMP ALTERNATOR/
GENERATOR/STARTER
TEST STAND