10-95. DIVERTER MANIFOLD AND HOUSING REPLACEMENT (Cont'd)
b. Installation
TM 9-2320-387-24-2
10-160
Change 1
1.
Position manifold and housing (9) under A-beam (1) and connect two defroster flex ducts (2) to
manifold and housing (9) with two clamps (4).
2.
Connect defroster cable core (12) to baffle pin (10) and install pushnut (11).
3.
Install duct (13) on manifold and housing (9) with four rivets (14).
NOTE
Ensure diverter control knob is pushed into cowl and baffle pin is in
the downward position before securing control cable to diverter box.
4.
Install clip (5) on manifold and housing (9) with screw (6).
5.
Install manifold and housing (9) on heater (7) with two screws (8).
6.
Install panel assembly (15) on A-beam (1) and right mounting bracket (3) with four screws (16).
1
4
9
14
11
16
12
13
15
10
2
3
5
8
7
6