TM 9-2320-387-24-l
1 2-46. STUICE-R
TEST PROCEDURES
(Contdl
STARTER MOTOR VOLTAGE TEST #68
Description:
Pre-Test Procedures:
This procedure measures the voltage
present at the starter motor positive
terminal in the 0 - 32 volts range.
Test requires DCA hookup only.
Run confidence test.
Typical Applications:
Check starter motor vottage.
Test Procedure:
1. Disconnect fuel solenoid wire 64A to prevent
starting.
2. Set TEST SELECT switch to 68.
3. Press and release TEST button.
4. Crank the engine and observe the displayed
voltage.
Control Functions:
01.02,03,
04,06
Possible Error Messages:
None.
2-497