TM 9-2320-362-14&P
Table 3-2.
Unit Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10. FUEL GAGE DISPLAYS READING OF MORE THAN 3/8-TANK FULL AND STATUS
INDICATOR ALARM AND LIGHT ARE ON (REFER TO FIGURES 3-l THRU 3-3)
Condition:
HMMWV engine has been running 10 to 15 minutes. Both
light and alarm tests on status indicator are normal.
NOTE
l
When measuring voltage, measure against ground.
l
Before starting procedure, see para 1-1.
Step 1.
Disconnect cable W64 from connector 12J1 on tach/hourmeter
box.
Step 2.
Using multimeter, measure voltage at connector 12J1, pin
E , on tach/hourmeter box.
If multimeter displays correct voltage (fig 3-3), go
to step 3.
If multimeter does
3), go to step 5.
Step 3.
Reconnect cable W64 to
box .
Disconnect cable
NOT display correct voltage (fig
connector 12J1 on tach/hourmeter
W64 from connector on shelter.
3-
Step 4.
Using multimeter, measure voltage at cable W64, pin E.
If multimeter displays correct voltage (fig 3-3),
refer to system manual for further troubleshooting.
If multimeter does NOT display correct voltage (fig 3-
3), replace faulty cable assembly W64 (para 3-25).
Step 5.
Reconnect cable W64 to connector 12J1 on tach/hourmeter
box.
Remove engine access cover and disconnect safety
lanyard.
Disconnect cable W66 from connector 12J2 on
tach/hourmeter box.
3-22