TM 9-2320-280-20-3
Section Il. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Contd)
Figure D-39. Battery Cable Assembly
INSTRUCTIONS:
1. Determine cable number needed from RPSTL and cut wire 6154-00-705-6674 to length as shown.
NOTE
Items 1, 4, 5, 6, and 7: flat of terminals to be 90° offset as shown without
wire twist.
Item 6: one terminal end is bent 30°.
2. Select and solder proper end terminals to cable ends as shown. (Refer to TM 9-237 for soldering
instructions.)
NOTE
Insulator boot 5582481 is installed on 30° bent terminal end of item 6.
3. Select and install proper insulators as shown.
4. Mark and install circuit number identification band and part, number identification band using old
cable as reference.
D-25