CLEAN AND TIGHTEN BATTERY TERMINALS AND CLAMPS
DISCONNECT WIRE 14A AT THE NEUTRAL SAFETY SWITCH. TURN ROTARY SWITCH TO START. IS THERE BATTERY VOLTAGE AT WIRE 14A (THE NEUTRAL SAFETY SWITCH END)?
TM-9-2320-280-20-1 Truck Utility Cargo/Troop 1-1/4 Ton 4x4 Manual
Page Navigation
346
347
348
349
350
351
352
353
354
355
356
TM 9-2320-280-20-1
REFERENCE INFORMATION
STARTER CIRCUIT
Replace cable, refer to (para 4-77).
Put the red lead on the power stud,
and the black on the terminal of the
starter in order to measure the
voltage along wire 6A.