TM 9-2320-362-14&P
4-18. EES KIT INSTALLATION (Contd)
2.
3.
4.
5.
6.
NOTE
After drilling holes, touch-up exposed surfaces
with paint to prevent corrosion.
Remove two screws (3) securing retaining rod (2) to cargo floor (4) and
remove retaining rod (2) from insulation blanket (10). Retain screws (3)
and retaining rod (2).
Remove one screw (12) and one retaining clip (11) holding insulation
retainer (5) to transmission tunnel (16).
Retain screw (12) and retaining
clip (11).
Remove one screw (1) and one bolt (9) securing insulation retainer (5)
to transmission tunnel (16) and remove insulation retainer (5). Retain
screw (1) and bolt (9).
Remove two screws (7) and one retainer (6) securing insulation
blanket (10) to floor (8).
Retain screws (7) and retainer (6).
Lift up right front cowl insulation (15) and remove two screws (14) and
one retainer (13) securing insulation blanket (10) to floor (8) and remove
insulation blanket (10).
Retain screws (14) and retainer (13).
4-42