INSTRUCTIONS:
NOTE
Ensure wire markers match letter identification for connector
and receptacle harness assemblies.
Trim excess wire to required length when installing wire and
terminal lugs to terminal block assembly.
1.
Connect wires (3) marked 2, 3, 4, 6, 7, and 16 on receptacle plug (4) to terminal strip (2) marked H, F,
G, C, D, and B.
2.
Connect wire (3) marked 13 on receptacle plug (4) to terminal strip (2) marked E.
3.
Connect wires (5) marked 1, 8, 11 on receptacle plug (4) to terminal strip (1) marked E, F, D.
4.
Connect wires (3) marked 5, 9, 10, and 12 on receptacle plug (4) to terminal strip (1) marked A, H, I,
and G.
TM 9-2320-280-20-3
D-94
Change 1
Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd)
Figure D-107. Receptacle Plug Installation.